Posted by: Mudassir Ali | August 11, 2010

Configuring Dynamic Hunt Groups

Dynamic Hunt Groups

Configuring Dynamic Hunt Groups

Create hunt groups that allow dynamic login and logout. In the hunt group below the ‘*’ denotes a wildcard slot for a single hunt group login. Up to 20 wildcard slots are allowed on the UC500.

config t
ephone-hunt 1 peer
pilot 255
list 201, *, *
final 298
no-reg pilot
statistics collect
ephone-hunt 1 peer
pilot 255
list 201, *, *
final 298
no-reg pilot
statistics collect

Add the ability for an ephone-dn to login or logout. In the ephone-dn of any extension you would like to have the ability to login or out of huntgroups needs the ‘ephone-hunt login’ command.

 ephone-dn 3 dual-line
 number 203 no-reg primary
 label 203
 description ccc Smith
 name ccc Smith
 call-forward busy 299
 call-forward noan 299 timeout 10
 corlist incoming user-domestic
 translation-profile incoming CallBlocking
 ephone-hunt login

Enable the feature access code(FAC) to allow the extension to dial the login and logout codes for the hunt group(s). There are two ways to add the access codes using fac standard or fac custom.

config t
telephony-service
fac standard
config t
telephony-service
fac custom ephone-hunt join *3
fac custom ephone-hunt cancel #3
end

Dynamic login to a hunt group when one hunt group is configured.

dial FAC code '*3'
 *3 login
 #3 logout

Dynamic login to a hunt group when multiple hunt groups are configured.

dial FAC code '*3 + hunt group pilot number'
 *3255# login
 #3255# logout

Advertisements

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s

Categories

%d bloggers like this: